Master Spas Spas 2008 Guide de dépannage Page 1

Naviguer en ligne ou télécharger Guide de dépannage pour Accessoires pour piscines hors sol Master Spas Spas 2008. Master Spas Spas 2008 Troubleshooting guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
DURA-JET
TM
SPA PUMP
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
© 2008 Pentair Water Pool and Spa, Inc.
All rights reservedThis document is subject to change without notice1620 Hawkins Ave., Sanford, NC 27330
• (919) 566-800010951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
Pentair Water Pool and Spa® is a registered trademark of Pentair Water Pool and Spa, Inc. Dura-Jet is a trademark of
Sta-Rite Industries, LLC. Other trademarks and trade names may be used in this document to refer to either the entities
claiming the marks and names or their products. Pentair Water Pool and Spa, Inc.disclaims proprietary interest in marks and
names of others.
P/N S377 (Rev A) - 04/14/08
This manual should be furnished
to the end user of this pump; its
use will reduce service calls,
chance of injury, and will lengthen
pump life.
CUSTOMER SUPPORT: CALL (800) 831- 7133
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - SPA PUMP

DURA-JETTMSPA PUMPO W N E R’ S M A N U A LINSTALLATION, OPERATION & PARTS© 2008 Pentair Water Pool and Spa, Inc. All rights reservedThis document

Page 2 - INSTRUCTIONS

10STORAGE/WINTERIZINGTo prevent damage to components fromfumes, store spa chemicals away from pump and spa.If possible, store chemicals in another roo

Page 3 - ELECTRICAL

11TROUBLESHOOTING GUIDERead and understand safety and operatinginstructions in this manual before doing any work onpump!A. PUMP DOES NOT OPERATE1. Che

Page 4 - Voltage:

12123456789102478 0596• Not illustrated.* Models DJAYFA-0062A, -0162A use Seal Part No. 37400-0028.REPAIR PARTS LISTDURA-JETTM“DJ” SPA PUMPKey PartN

Page 5

13Parts are common to all models listed except as noted;Motor (Key No. 1), Impeller (Key No. 6), and Volute (Key No. 7) are listed below.Motor Package

Page 6

14123456789102478 0596• Not illustrated.* Models DJAYFA-0062A, -0162A use Seal Part No. 37400-0028.REPAIR PARTS LISTDURA-JETTM“DJ” SPA PUMPKey PartN

Page 7

15Parts are common to all models listed except as noted;Motor (Key No. 1), Impeller (Key No. 6), and Volute (Key No. 7) are listed below.Motor Package

Page 8 - OPERATION

16123456789102478 0596• Not illustrated.* Models DJAYFA-0062A, -0162A use Seal Part No. 37400-0028.REPAIR PARTS LISTDURA-JETTM“DJ” SPA PUMPKey PartN

Page 9 - PUMP SERVICE

17Parts are common to all models listed except as noted;Motor (Key No. 1), Impeller (Key No. 6), and Volute (Key No. 7) are listed below.Motor Package

Page 12 - “DJ” SPA PUMP

READ AND FOLLOW ALL INSTRUCTIONS!This is the safety alert symbol. When you see thissymbol on your system or in this manual, look forone of the followi

Page 13

READ, THEN KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCES377 (Rev. A) 04-14-08*S377*

Page 14

3INSTALLATIONInstallation and wiring of pump should only be doneby qualified, licensed personnel.Pump mount must:Be Solid - Level - Rigid - Vibration

Page 15

4Install and bond pump according to local codes andordinances; use bonding lug on motor (see Figure 1). Usesolid copper conductor No. 8 AWG (8.4mm2) o

Page 16

5BranchAWG (mm2) Wire Gauge Size at 90° CVoltage/ Full Circuit Dist in Ft. (M) - Service to MotorModel Hertz Load Breaker 0-100 101-200 201-300No. (

Page 17

6BranchAWG (mm2) Wire Gauge Size at 90° CVoltage/ Full Circuit Dist in Ft. (M) - Service to MotorModel Hertz Load Breaker 0-100 101-200 201-300No. (

Page 18

7BranchAWG (mm2) Wire Gauge Size at 90° CVoltage/ Full Circuit Dist in Ft. (M) - Service to MotorModel Hertz Load Breaker 0-100 101-200 201-300No. (

Page 19

8OPERATIONPriming Pump:NEVER run pump dry! Running pump drymay damage seals, causing leakage and flooding! Fillpump with water before starting motor.D

Page 20 - S377 (Rev. A) 04-14-08

9PUMP SERVICEHazardous voltage. Can shock, burn,orcause death. Disconnect power before working on pumpor motor.Pump should only be serviced by qualifi

Commentaires sur ces manuels