Master Spas H2X Manuel du propriétaire Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 46
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
Do Not Dive.
32
MASTER SPA - H2X
Diagnostic Messages
Message
Meaning
No message on display.
Power has been cut off to the spa.
Temperature is unknown.
"Overheat" - The swim spa has shut down.
One of the sensors has detected
118˚F/48˚C at the heater.
"Overheat" - The swim spa has shut down.
One of the sensors has detected that the
swim spa water is 110˚F/43˚C.
"Ice" - Potential freeze condition
detected.
Swim spa is shut down. The sensor that is
plugged into the Sensor "A" jack is not
working.
Swim spa is shut down. The sensor that is
plugged into the Sensor "B" jack is not
working.
Sensors are out of balance. If alternating
with swim spa temperature, it may just be
a temporary condition. If flashing by itself,
spa is shut down.
A significant difference between the
temperature sensors has been detected.
This could indicate a flow problem.
Persistent low flow problems. (Displays on
the fifth occurrence of "HL" message
within 24 hours.) Heater is shut down,
but other swim spa functions continue to
run normally.
Action Required
The control panel will be disabled until power
returns. Time of day will be preserved for
30 days on your system. Spa settings are
preserved on all systems.
After the pump has been running for 2 minutes,
the temperature will be displayed.
DO NOT ENTER THE WATER.
Remove the swim
spa cover and allow water to cool. Once the heater has
cooled, reset by pushing any button. If swim spa does
not reset, shut off the power to the swim spa and call
your dealer or service organization.
DO NOT ENTER THE WATER.
Remove the swim
spa cover and allow water to cool. At 107˚F/ 42˚C,
the swim spa should automatically reset. If spa does
not reset, shut off the power to the swim spa and call
your dealer or service organization.
No action required. The pumps will automatically
activate regardless of spa status.
If the problem persists, contact your dealer or
service organization. (May appear temporarily in
an overheat situation and disappear when the
heater cools.)
If the problem persists, contact your dealer or
service organization. (May appear temporarily in
an overheat situation and disappear when the
heater cools.)
If the problem persists, contact your dealer or
service organization.
Check water level in swim spa. Refill if necessary.
If the water level is okay, make sure the pumps
have been primed. If problem persists, contact
your dealer or service organization.
Follow action required for "HL" message.
Heating capacity of the swim spa will not reset
automatically; you may press any button to reset.
07MS H2X Owners Manual 1/10/07 11:30 PM Page 32
Vue de la page 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 45 46

Commentaires sur ces manuels

Pas de commentaire